CFP last date
20 May 2024
Reseach Article

Stent Fitting using Cylindrical Affine Transformation Model for Pulmonary Artery

by Himani Arora, K. K. Shukla, Luc Duong
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 70 - Number 19
Year of Publication: 2013
Authors: Himani Arora, K. K. Shukla, Luc Duong
10.5120/12177-8226

Himani Arora, K. K. Shukla, Luc Duong . Stent Fitting using Cylindrical Affine Transformation Model for Pulmonary Artery. International Journal of Computer Applications. 70, 19 ( May 2013), 36-41. DOI=10.5120/12177-8226

@article{ 10.5120/12177-8226,
author = { Himani Arora, K. K. Shukla, Luc Duong },
title = { Stent Fitting using Cylindrical Affine Transformation Model for Pulmonary Artery },
journal = { International Journal of Computer Applications },
issue_date = { May 2013 },
volume = { 70 },
number = { 19 },
month = { May },
year = { 2013 },
issn = { 0975-8887 },
pages = { 36-41 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume70/number19/12177-8226/ },
doi = { 10.5120/12177-8226 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T21:33:18.447725+05:30
%A Himani Arora
%A K. K. Shukla
%A Luc Duong
%T Stent Fitting using Cylindrical Affine Transformation Model for Pulmonary Artery
%J International Journal of Computer Applications
%@ 0975-8887
%V 70
%N 19
%P 36-41
%D 2013
%I Foundation of Computer Science (FCS), NY, USA
Abstract

The stents are becoming widely used as percutaneous interventions of pulmonary artery are progressively replacing conventional open heart surgeries. Presently, X-ray images of pulmonary artery i. e. angiograms are visually inspected by physician to determine the proper stent size. The size estimation of stent done preoperative which has not been assessed so far, is studied in this paper. A reliable method to determine the size of stent using a deformation model before performing angioplasty is proposed. A cylindrical affine transformation model is used to predict the expected deformation of the stent to fit it as closely as possible into artery. The method was evaluated on artery data set of 5 cases in which the patient was suffering from stenosis of pulmonary artery to obtain satisfactory results.

References
  1. Rashkind WJ, Miller WW. Creation of an Atrial Septal Defect Without Thoracotomy: A Palliative Approach to Complete Transposition of the Great Arteries. JAMA. 1966;196(11):991-992.
  2. Dotter CT, Judkins MP. Transluminal Treatment of Arteriosclerotic Obstruction. Description of a New Technic and a Preliminary Report of Its Application. Circulation. 1964;30:654–70.
  3. Peters B, Ewert P, Berger F. The role of stents in the treatment of congenital heart disease: Current status and future perspectives. Ann Pediatr Cardiol. 2009;2:3–23.
  4. Balcon R, Beyar R, Chierchia S, et al. Recommendations on stent manufacture, implantation and utilization. Study group of the working group on coronary circulation. Eur Heart J 1997;18:1536–47.
  5. Serruys PW, de Jaegere P, Kiemeneij F, et al. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent study group. N Engl J Med 1994;331:489–95.
  6. Fischman DL, Leon MB, Baim DS, Schatz RA, Savage MP, Penn I, et al. Stent Restenosis Study Investigators. A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. N Engl J Med. 1994;331:496–501.
  7. Macaya C, Serruys PW, Ruygrok P, Suryapranata H, Mast G, Klugmann S, Urban P, den Heijer P, Koch K, Simon R, et al. Continued benefit of coronary stenting versus balloon angioplasty: one-year clinical follow-up of Benestent trial. Benestent Study Group. J Am Coll Cardiol. 1996 Feb;27(2):255–261.
  8. Hendijani N, Manteghi M. Application of singularity expansion method in estimating size of a stent implanted in the artery. Antennas and Propagation (APSURSI), 2011 IEEE International Symposium, 2011 July, pp. 131-133.
  9. Jenkins JH, Morrien JP, Bouissaghouane K, Solomon HP. System, method and computer instructions for estimating stent size. EPO Patent EP1700566, filed March 08, 2006, and issued Sept 13, 2006.
  10. Voigt I,Mengue EA, Ionasec R, Mansi T, Georgescu B, Hornegger J, Comaniciu D. Model-based Postoperative Modeling of Stent-Based Devices from CT: Application to TAVI. MICCAI 2012 – Workshop MICCAI-STENT 2012, Nice, France, October 1-5 2012.
  11. Wentzel JJ, Whelan DM, van der Giessen WJ, van Beusekom HM, Andhyiswara I, Serruys PW, Slager CJ, Krams R. Coronary stent implantation changes 3-D vessel geometry and 3-D shear stress distribution. Journal of Biomechanics. 2000;33:1287–1295.
  12. Tu S, Huang Z, Koning G, et al. A novel three-dimensional quantitative coronary angiography system: in vivo comparison with intravascular ultrasound for assessing arterial segment length. Catheter Cardiovasc Interv. 2010;76:291–298
  13. Top A, Hamarneh G, Abugharbieh R. Active Learning for Interactive 3D Image Segmentation. In Medical Image Computing and Computer-Assisted Intervention (MICCAI), volume 6893, pages 603-610, 2011.
  14. Top A, Hamarneh G, Abugharbieh R. Spotlight: Automated Confidence-based User Guidance for Increasing Efficiency in Interactive 3D Image Segmentation. In Medical Image Computing and Computer-Assisted Intervention Workshop on Medical Computer Vision (MICCAI MCV), pages 204-213, 2010.
  15. Tanner C, Carter T, Hawkes DJ, Székely G. Cylindrical affine transformation model for image registration. Proc. SPIE Medical Imaging: Image Processing 2010, vol. 7623, pp. 76232P-76232P-6.
  16. Weisstein, Eric W. "Point-Line Distance--3-Dimensional. " From MathWorld--A Wolfram Web Resource. http://mathworld. wolfram. com/Point-LineDistance3-Dimensional. html
  17. de Boor, C. , A Practical Guide to Splines, Springer-Verlag, 1978.
Index Terms

Computer Science
Information Sciences

Keywords

Percutaneous interventions Stent Fitting Pulmonary artery Cylindrical Affine Transformation Stenosis